Remove the probe's own setup
/modules/{moduleId}/irrigation/installation The probe falls back on its parcel’s setup. The current version is CLOSED, never deleted: the equipment past waterings were converted with stays readable.
Path parameters
-
moduleIdinteger required
Headers
-
Idempotency-KeystringReplays the same 2xx response (24 h)
Response
Number of versions closed + resulting configuration
-
closedinteger -
configIrrigationConfigEverything governing how a probe’s waterings are converted, in one call.
Show 10 attributes Hide attributes
-
moduleIdinteger -
parcelIdinteger nullable -
installationIrrigationInstallation nullableSetup EFFECTIVE today, after scope resolution.
null= no setup.Show 13 attributes Hide attributes
-
idinteger -
scopestringScope. A probe setup wins AS A WHOLE over its parcel’s — never field by field.
-
parcelIdinteger nullable -
moduleIdinteger nullable -
systemstringType of equipment. Determines the default wetted soil fraction (FAO-56 table 20):
drip0.35 ·micro_sprinkler0.60 · all others 1.00. -
flowMmPerHnumber nullableApplication rate in mm/h. Computed when the drip geometry is provided (
emitterFlowLph×emittersPerM2), otherwise entered directly — it is the manufacturer’s unit for sprinkler and pivot systems.null: a duration will not be convertible into mm. -
emitterFlowLphnumber nullableFlow rate of ONE emitter, in L/h. This is what is printed on the equipment.
-
emittersPerM2number nullableDensity of emitters per m². Nobody knows this figure off the top of their head: it follows from the spacings — 1 ÷ (emitter spacing × lateral spacing, in m), or (emitters per tree) ÷ (area per tree).
-
fractionWettednumberWetted soil fraction (fw, FAO-56 table 20), 0 < fw ≤ 1. Always filled in: the entered value, otherwise the system default. Not something to ask a farmer.
-
fractionWettedIsDefaultbooleantrue = comes from the system default, never entered.
-
irrigatedAreaM2number nullableIrrigated area in m². Required to convert a volume into mm.
-
validFromstring date-timeDate this version TAKES EFFECT in the field.
-
validTostring date-time nullableUpper bound, EXCLUDED.
null= current version.
-
-
defaultFractionWettednumber nullableWhat fw would be if it were not entered.
-
placementIrrigationPlacement nullablePosition of the probe relative to the emitter. ⚠️ It enters NO calculation and must not: it is an observation variable, meant to explain after the fact why a sensor stays silent (probe planted outside the wetted bulb).
Show 3 attributes Hide attributes
-
emitterDistanceCminteger nullableDistance to the nearest emitter, in cm. 0 is legitimate.
-
notesstring nullable -
setAtstring date-time
-
-
canGeneralizebooleanCan this probe’s setup be pushed up to the parcel?
-
hasParcelInstallationbooleanIs there a parcel setup to fall back on?
-
siblingOverridesintegerNumber of OTHER probes on the parcel carrying their own current setup — what
generalizewithdropSiblingswould overwrite. -
versionsarray of IrrigationInstallationVersionFull history applicable to this probe — its own versions AND its parcel’s, each tagged with its scope, most recent first.
Show 15 attributes Hide attributes
-
idinteger -
scopestringScope. A probe setup wins AS A WHOLE over its parcel’s — never field by field.
-
parcelIdinteger nullable -
moduleIdinteger nullable -
systemstringType of equipment. Determines the default wetted soil fraction (FAO-56 table 20):
drip0.35 ·micro_sprinkler0.60 · all others 1.00. -
flowMmPerHnumber nullableApplication rate in mm/h. Computed when the drip geometry is provided (
emitterFlowLph×emittersPerM2), otherwise entered directly — it is the manufacturer’s unit for sprinkler and pivot systems.null: a duration will not be convertible into mm. -
emitterFlowLphnumber nullableFlow rate of ONE emitter, in L/h. This is what is printed on the equipment.
-
emittersPerM2number nullableDensity of emitters per m². Nobody knows this figure off the top of their head: it follows from the spacings — 1 ÷ (emitter spacing × lateral spacing, in m), or (emitters per tree) ÷ (area per tree).
-
fractionWettednumberWetted soil fraction (fw, FAO-56 table 20), 0 < fw ≤ 1. Always filled in: the entered value, otherwise the system default. Not something to ask a farmer.
-
fractionWettedIsDefaultbooleantrue = comes from the system default, never entered.
-
irrigatedAreaM2number nullableIrrigated area in m². Required to convert a volume into mm.
-
validFromstring date-timeDate this version TAKES EFFECT in the field.
-
validTostring date-time nullableUpper bound, EXCLUDED.
null= current version. -
setAtstring date-timeDate it was ENTERED, distinct from
validFrom, which is the date it takes effect in the field. -
notesstring nullable
-
-
missingDosesobjectRecorded waterings whose dose could never be computed.
Show 3 attributes Hide attributes
-
countinteger -
withoutInstallationintegerThe share of them that no
recomputewill ever be able to complete: no setup version covers their date. The useful move is then to declare a retroactive setup. -
oldestWithoutInstallationstring date-time nullable
-
-
Errors
- 400
Invalid body
- 401
Not authenticated
- 403
Insufficient scope/role, or outside your company