Skip to content

Root-zone weighted series

GET /modules/{id}/measurements/weighted
  • Scope readings:read
  • API key x-api-key
  • Base URL https://api.hub.akuasense.com/v1

Path parameters

  • id integer required

Query parameters

  • type string

    Quantity to read. tensio: tensiometer probe — tension, its former code, is still accepted. A module that carries only one sensor type serves that one, whatever the type requested.

    Values: humiditytemperaturetensio
    Default: humidity
  • start string date-time
  • end string date-time
  • interval integer

    Bucket (seconds)

Response

200

Root-zone weighted series

  • module_id integer always present
  • type string always present

    Type actually served (see DepthSeries).

    Values: humiditytemperaturetensio
  • unit string always present

    Unit of the main quantity: % (value_vwc, value_vwc_max), °C (value_temp) or kPa (value_tensio). value_mm is always in mm.

  • start string date-time always present
  • end string date-time always present
  • interval_seconds integer nullable always present

    See DepthSeries.

  • data array of WeightedSeriesPoint always present

    One instant of the weighted series. Only the fields of the type served are present; values to one decimal place. Sensor error codes: see the general API description.

    Show 6 attributes Hide attributes
    • time string date-time always present
    • value_vwc number nullable

      Mean moisture, %, weighted like the hub’s summary curve: per-depth weights entered in the probe’s Settings, otherwise the FAO-56 root water uptake distribution (40/30/20/10 per quarter of the root zone), otherwise a plain average.

    • value_vwc_max number nullable

      The same average, relative to the maximum the soil can hold, %.

    • value_mm number nullable

      Water stock, mm: the water held in the declared root zone (crop or manual depth), otherwise in the column the probe monitors. Each sensor is weighted there by the thickness of its soil slice, not by its uptake weight: the figure is therefore directly comparable to rainfall or to an irrigation application. A slice with no value at that instant is estimated from the others. null on a single-sensor probe with no declared root zone.

    • value_temp number nullable

      Temperature series: weighted average, °C.

    • value_tensio number nullable

      Tensiometer probe: weighted average, kPa.

Errors

  • 400

    Invalid parameter

    invalid_idinvalid_date
  • 401

    Not authenticated

  • 403

    Insufficient scope, or resource outside your company